BXZMK - 00741 WELDERS ANTI SPATTER, 00741
- MSDS: BXZMK
- Manufacturer: SPRAYON PRODUCTS
- Product Name: 00741 WELDERS ANTI SPATTER, 00741
- National Stock Number: 6850-00N009121
Product Identification
Product ID:00741 WELDERS ANTI SPATTER, 00741
MSDS Date:08/03/1988
FSC:6850
NIIN:00N009121
MSDS Number: BXZMK
Responsible Party
BEDFORD HTS, OH 44146
US
Emergency Phone: 216-292-7400
Info Phone: 216-292-7400
Cage: 09800
Contractor
Telephone: 216-292-7400 OR 216-595-8634
Cage: 09800
Ingredients
TALC (POWDER), CONTAINING NO ASBESTOS FIBERS; (MAGNESIUM
CAS: 14807-96-6
RTECS: MW2700000
Fraction By Weight: 5%
OSHA PEL 0.2 FIBERS/CC
ACGIH TLV: 0.2 FIBER/CC, A1
ETHANE, 1,1,1-TRICHLORO-; (METHYL CHLOROFORM) (SARA 313)
CAS: 71-55-6
RTECS: KJ2975000
Fraction By Weight: 90%
OSHA PEL 350 PPM
ACGIH TLV: 350 PPM/450 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
CARBON DIOXIDE
CAS: 124-38-9
RTECS: FF6400000
Fraction By Weight: <5%
OSHA PEL 5000 PPM
ACGIH TLV: 5000 PPM/30000 STEL
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:IN CONFINED AREA VAPS IN HIGH
CONC ARE ANESTH. IRRITANT TO SKIN & UPPER RESP SYS. OVEREXP MAY
RSLT IN LIGHT-HEADEDNESS, STAGG GAIT, GIDDINESS & POSS NAUS.
HARMFUL/FATAL IF SWALLOWED. CHRONIC:RPT S HAVE ASSOC RPTD & PRLNGD
OVEREXP TO SOLVS W/PERM BRAIN & NERV SYSTEM DAMAGE, ALSO KIDNEY &
LIVER (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:DAMAGE. CHLOROCARBON MATLS HAVE PRDCED
SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE A
SIMILAR EFT IN HUMANS. ADRENOMIMETICS (E.G. EPINEPHRINE) MAY BE
CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES IN HUMANS ACUTELY
OR CHRONICALLY EXPOSED TO CHLOROCARBONS .
Medical Cond Aggravated by Exposure:NONE.
First Aid
First Aid:INHAL:REMOVE PATIENT TO FRESH AIR. EYES:FLUSH WITH WATER FOR
@ LEAST 15 MINUTES. SKIN:WASH WITH SOAP & WATER. INGEST:CALL
PHYSICIAN IMMEDIATELY. DO NOT INDUCE VOMITING.
Fire Fighting
Flash Point:<21F,<-6C
Lower Limits:SEE ING 2
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL OR FOAM.
Fire Fighting Procedures:NIOSH/MSHA APPRVD PRESS DEMAND SCBA & FULL
PROT EQUIP . WATER MAY BE INEFTIVE. WATER MAY USED TO KEEP FIRE
EXPOSED CONTAINERS COOL.
Unusual Fire/Explosion Hazard:THERM DECOMP PRODS MAY INCL HCL &
PHOSGENE . DO NOT SPRAY NEAR OPEN FLAME. KEEP @ ROOM TEMP AS EXPOS
TO DIRECT SUNLIGHT/OTHER HEAT MAY CAUSE BURSTING.
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION, VENTILATE,
AVOID BREATHING VAPORS AND REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT STORE ABOVE 120F. KEEP @ ROOM
TEMP AS EXPOS TO DIRECT SUNLIGHT/HEAT MAY CAUSE BURSTING. KEEP AWAY
FROM CHILDREN. DO NOT PUNCTURE/INCIN.
Other Precautions:DO NOT SPRAY NEAR FIRE/OPEN FLAME. NO SMOKING IN AREA
OF USE. DO NOT USE IN GEN VICINITY OF ARC WELDING, OPEN FLAMES OR
HOT SURFACES. HEAT &/OR UV RADIA MAY CAUSE FORMATION OF HCL &/OR
PHOSGENE .
Exposure Controls
Respiratory Protection:IF PERSONAL EXPOS CANNOT BE CONTROLLED BELOW
APPLIC LIMS BY VENT, WEAR PROPERLY FITTED ORG VAP/PARTICULATE RESP
APPRVD BY NIOSH/MSHA FOR PROT AGAINST MATLS IN INGREDS. WHEN
SANDING/ABRADING DRIED FILM , WEAR DUST/MIST RESP APPRVD (SUPDAT)
Ventilation:PROVIDE LOC EXHAUST VENT IN VOL & PATTERN TO KEEP TLV OF
ALL HAZ INGREDS BELOW ACCEPTABLE LIM, & LEL BELOW STATED LIMIT.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORK GOGG .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
VP:85 +/-5 PSIG. RESP PROT:BY NIOSH/MSHA FOR DUST WHICH MAY BE
GENERATED FROM PROD, UNDERLYING PAINT, OR ABRASIVE.
Chemical Properties
Boiling Pt:B.P. Text:<0F,<-18C
Vapor Pres:SUPDAT
Vapor Density:HVR/AIR
Evaporation Rate & Reference:FASTER THAN ETHER
Appearance and Odor:COATINGS
Percent Volatiles by Volume:93
Stability
Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:DO NOT STORE ABOVE 120F.
Hazardous Decomposition Products:BY OPEN FLAME:CARBON MONOXIDE, CARBON
DIOXIDE, HYDROGEN CHLORIDE, AND PHOSGENE GAS.
Disposal
Waste Disposal Methods:DO NOT INCINERATE-DISPOSE IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL REGULATIONS REGARDING POLLUTION.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.